As an operator, knowing the symptoms of a wet scrubber malfunction can help you minimize downtime while ensuring your system continues to operate efficiently.

Common Wet Scrubber Troubleshooting Fixes

Pinpointing the cause of a wet scrubber malfunction can save valuable time and reduce downtime. Some symptoms of a wet scrubber malfunction and their troubleshooting actions include:

Degraded Performance

One of the most common problems wet scrubbers experience is degraded performance, which can manifest in the following symptoms:

  • Low or high pressure.
  • Changes in pH levels outside of the standard operating range.
  • Low or high flow rates.
  • Out-of-family exhaust samples.
  • Abnormal fluid samples.

To determine if these symptoms indicate a problem, take the following steps:

  • Record the current readings for flow rate, temperature, pH, pressure drop and other factors the manufacturer says is important in the operation of your system, then compare these readings to the system’s design specifications and historical data.
  • Carefully inspect the system’s interior and look for blockages from algae, bacteria or sediment.
  • Take a sample of the scrubbing liquid to verify the chemical concentration and pH.

Potential Causes and Solutions for Degraded Performance

SymptomCauseTroubleshooting Action
Low pressure or flow rateBlockage in the pipes, nozzles or packing, or a leak in the ductwork or housing.Clean or replace the clogged components. Inspect and repair system leaks.
High pressure or flow rateClogged mist eliminator or packing bed. Increased demand on the system or higher fan speed.Clean the mist eliminator and packing. Verify the correct fan speed settings and system parameters.
Deviations in pH levelsChemical imbalances or unanticipated chemicals in the gas stream.Check for leaks, organic growth or corrosion. Replenish or replace the scrubbing solution. Examine new chemical introductions.
High energy consumptionFailing sensor or mechanical issues like a failing pump motor.Recalibrate the sensors. Conduct a pump performance assessment.

Temperature Anomaly

If the wet scrubber’s operating temperature is consistently above or below the recommended range, perform the following to verify that a malfunction is occurring:

  • Use a calibrated, independent thermometer to check the temperature and confirm an accurate sensor reading. Be sure to do this at the location where you are getting the reading.
  • Check the heat exchanger to confirm proper function.
  • Review the inlet gas conditions to verify if the temperature has changed due to modifications to the upstream process.

Potential Causes and Solutions for Temperature Anomalies

SymptomCauseTroubleshooting Action
High gas temperatureMalfunctioning heat exchanger, faulty temperature sensor or increased inlet gas temperature.Inspect, clean or repair the heat exchanger. Calibrate or replace the sensor. Identify and correct any upstream process changes that deviate from standard operating conditions.
Low gas temperatureMalfunctioning heat exchanger, faulty temperature sensor or decreased inlet gas temperature.Inspect, clean or repair the heat exchangers. Calibrate or repair the sensor. Identify and correct any upstream process changes that deviate from standard operating conditions.

Pump-Related Issues

The pump is essential to the wet scrubber’s liquid delivery system, and a malfunction will present obvious signs of failure:

  • Grinding, rattling or high-pitched whining noises.
  • Excessive vibration.
  • Hot to the touch — most pumps shouldn’t be hotter than 140 degrees Fahrenheit.
  • High energy consumption.
  • Low pump pressure or flow rate.

Here are some ways to determine if these symptoms signify a larger malfunction:

  • Record values such as speed, pressure and flow rate, and compare them to historic data.
  • Listen to the sounds the pump is making and check for excessive vibration or heat.
  • Check around the seals and connections for leaks.

Potential Causes and Solutions for Pump-Related Issues

SymptomCauseTroubleshooting Action
Noise, heat or vibrationBearing failure or pump and motor misalignment.Shut the wet scrubber down and replace bearings or realign the pump and motor.
High pump pressurePlugged nozzle, worn packing or pump controller malfunction.Clean the system nozzle or replace the pump packing.
Low pressure or flow rateThe impeller is damaged or eroded, sediment is clogging the pump, the pump controller is malfunctioning or the packing is worn or has a low motor speed.Inspect and replace the impeller, disassemble and clean the pump, replace the packing or verify the motor speed.
Overheating/high energy useBearing failure causing friction. Internal friction from a sediment buildup or dielectric breakdown of the insulation in the motor coils.Install new bearings or disassemble and clean the pump. Replace the pump if the windings are damaged.

Why Trust Us for Your Wet Scrubber Needs?

At MACH Engineering, we understand the critical role wet scrubbers play in maintaining efficient operations. We have over 25 years of experience designing wet scrubber systems for industries including manufacturing, chemical processing, steel milling and agriculture. Our team combines hands-on experience with advanced processes to deliver practical designs.

In addition to equipment, we provide comprehensive support to ensure your wet scrubber operates at peak performance. From initial assessment to ongoing support, our team is dedicated to your success, and we provide custom solutions tailored to your specific product needs. Trust MACH Engineering to keep your facility running smoothly and efficiently.

Contact Us for Troubleshooting Assistance

Choose MACH Engineering for a reliable wet scrubber replacement for your operations. We custom-build all of our equipment, ensuring reliability. Contact us to learn more about our troubleshooting solutions or explore our replacement options.

Contact Us for Troubleshooting Assistance

Munira Marvi

Munira Marvi

Position

Munira Marvi is a Process Engineer at MACH Engineering, LLC, where she combines her chemical engineering expertise from the University of Houston with practical industry experience. Since joining the team in 2017, she has played a pivotal role in enhancing the company's technical capabilities and online presence. Specializing in process simulations and hydraulics calculations, Munira's work has significantly improved the performance and design of air and water pollution control equipment. Her project management experience spans the entire sales pipeline, from initial proposal development through final delivery, with a strong focus on maintaining clear client communication throughout each project phase. Munira's technical proficiency extends to AutoCAD design review, fabrication process optimization, and the implementation of advanced engineering solutions. Her commitment to precision and excellence has contributed to MACH Engineering's reputation for delivering high-quality industrial process solutions.